Commissioning an Elekta Versa HD linear accelerator G Narayanasamy, D Saenz, W Cruz, CS Ha, N Papanikolaou, S Stathakis Journal of applied clinical medical physics 17 (1), 179-191, 2016 | 70 | 2016 |
Dosimetric differences in flattened and flattening filter-free beam treatment plans Y Yan, P Yadav, M Bassetti, K Du, D Saenz, P Harari, BR Paliwal Journal of Medical Physics 41 (2), 92-99, 2016 | 34 | 2016 |
Deep learning‐based survival analysis for brain metastasis patients with the national cancer database N Bice, N Kirby, T Bahr, K Rasmussen, D Saenz, T Wagner, ... Journal of applied clinical medical physics 21 (9), 187-192, 2020 | 32 | 2020 |
A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans DL Saenz, BR Paliwal, JE Bayouth Journal of Medical Physics 39 (2), 64-70, 2014 | 31 | 2014 |
Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications DN Makris, EP Pappas, E Zoros, N Papanikolaou, DL Saenz, ... Physics in Medicine & Biology 64 (10), 105009, 2019 | 30 | 2019 |
Dosimetric validation of Monaco treatment planning system on an Elekta Versa HD linear accelerator G Narayanasamy, DL Saenz, D Defoor, N Papanikolaou, S Stathakis Journal of Applied Clinical Medical Physics 18 (6), 123-129, 2017 | 27 | 2017 |
Evaluation of the Elekta Agility MLC performance using high‐resolution log files CN Kabat, DL Defoor, P Myers, N Kirby, K Rasmussen, DL Saenz, ... Medical physics 46 (3), 1397-1407, 2019 | 25 | 2019 |
Characterization of a 0.35T MR system for phantom image quality stability and in vivo assessment of motion quantification DL Saenz, Y Yan, N Christensen, MA Henzler, LJ Forrest, JE Bayouth, ... Journal of applied clinical medical physics 16 (6), 30-40, 2015 | 20 | 2015 |
Dose calculation comparisons between three modern treatment planning systems C Bosse, G Narayanasamy, D Saenz, P Myers, N Kirby, K Rasmussen, ... Journal of medical physics 45 (3), 143-147, 2020 | 19 | 2020 |
A dosimetric analysis of a spine SBRT specific treatment planning system DL Saenz, R Crownover, S Stathakis, N Papanikolaou Journal of applied clinical medical physics 20 (1), 154-159, 2019 | 19 | 2019 |
Quantifying false positional corrections due to facial motion using SGRT with open‐face Masks V Bry, AL Licon, J McCulloch, N Kirby, P Myers, D Saenz, S Stathakis, ... Journal of Applied Clinical Medical Physics 22 (4), 172-183, 2021 | 14 | 2021 |
Dosimetric and localization accuracy of Elekta high definition dynamic radiosurgery DL Saenz, Y Li, K Rasmussen, S Stathakis, E Pappas, N Papanikolaou Physica Medica 54, 146-151, 2018 | 14 | 2018 |
Patient‐specific dose quality assurance of single‐isocenter multiple brain metastasis stereotactic radiosurgery using PTW Octavius 4D J McCulloch, J Pawlowski, N Kirby, K Rasmussen, Z Shi, P Myers, ... Journal of Applied Clinical Medical Physics 21 (9), 107-115, 2020 | 13 | 2020 |
End to end comparison of surface‐guided imaging versus stereoscopic X‐rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel … V Bry, D Saenz, E Pappas, G Kalaitzakis, N Papanikolaou, K Rasmussen Journal of Applied Clinical Medical Physics 23 (5), e13576, 2022 | 12 | 2022 |
The level of detail required in a deformable phantom to accurately perform quality assurance of deformable image registration DL Saenz, H Kim, J Chen, S Stathakis, N Kirby Physics in Medicine & Biology 61 (17), 6269, 2016 | 10 | 2016 |
Effect of electron contamination on in vivo dosimetry for lung block shielding during TBI G Narayanasamy, W Cruz, DL Saenz, S Stathakis, N Papanikolaou, ... Journal of Applied Clinical Medical Physics 17 (3), 486-491, 2016 | 10 | 2016 |
Pinnacle3 modeling and end‐to‐end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter‐free modes DL Saenz, G Narayanasamy, W Cruz, N Papanikolaou, S Stathakis Journal of Applied Clinical Medical Physics 17 (1), 192-206, 2016 | 9 | 2016 |
Commissioning and cross‐comparison of four scanning water tanks D Saenz, J Roring, W Cruz, V Sarkar, N Papanikolaou, S Stathakis Int J Cancer Ther Oncol 4 (1), 2016 | 8 | 2016 |
Clinical evaluation of a two-dimensional liquid-filled ion chamber detector array for verification of high modulation small fields in radiotherapy M Markovic, G Narayanasamy, S Stathakis, P Mavroidis, IA Jurkovic, ... Journal of Medical Physics 44 (2), 91-98, 2019 | 7 | 2019 |
A method to predict patient‐specific table coordinates for quality assurance in external beam radiation therapy DL Saenz, NR Astorga, N Kirby, M Fakhreddine, K Rasmussen, ... Journal of applied clinical medical physics 19 (5), 625-631, 2018 | 6 | 2018 |