Physicochemical Characterization and In Vitro Hemolysis Evaluation of Silver Nanoparticles J Choi, V Reipa, VM Hitchins, PL Goering, RA Malinauskas Toxicological Sciences 123 (1), 133-143, 2011 | 319 | 2011 |
Assessment of CFD performance in simulations of an idealized medical device: results of FDA’s first computational interlaboratory study SFC Stewart, EG Paterson, GW Burgreen, P Hariharan, M Giarra, ... Cardiovascular Engineering and Technology 3, 139-160, 2012 | 209 | 2012 |
Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices RA Malinauskas Artificial organs 21 (12), 1255-1267, 1997 | 159 | 1997 |
FDA benchmark medical device flow models for CFD validation RA Malinauskas, P Hariharan, SW Day, LH Herbertson, M Buesen, ... Asaio Journal 63 (2), 150-160, 2017 | 154 | 2017 |
Multilaboratory particle image velocimetry analysis of the FDA benchmark nozzle model to support validation of computational fluid dynamics simulations P Hariharan, M Giarra, V Reddy, SW Day, KB Manning, S Deutsch, ... | 151 | 2011 |
Comparison of two platelet activation markers using flow cytometry after in vitro shear stress exposure of whole human blood Q Lu, RA Malinauskas Artificial organs 35 (2), 137-144, 2011 | 85 | 2011 |
Results of FDA’s first interlaboratory computational study of a nozzle with a sudden contraction and conical diffuser SFC Stewart, P Hariharan, EG Paterson, GW Burgreen, V Reddy, SW Day, ... Cardiovascular Engineering and Technology 4, 374-391, 2013 | 71 | 2013 |
Multilaboratory study of flow‐induced hemolysis using the FDA benchmark nozzle model LH Herbertson, SE Olia, A Daly, CP Noatch, WA Smith, MV Kameneva, ... Artificial organs 39 (3), 237-248, 2015 | 64 | 2015 |
In vitro shear stress‐induced platelet activation: sensitivity of human and bovine blood Q Lu, BV Hofferbert, G Koo, RA Malinauskas Artificial organs 37 (10), 894-903, 2013 | 60 | 2013 |
Effects of thrombosed vena cava filters on blood flow: flow visualization and numerical modeling SFC Stewart, RA Robinson, RA Nelson, RA Malinauskas Annals of biomedical engineering 36, 1764-1781, 2008 | 48 | 2008 |
Inter-laboratory characterization of the velocity field in the FDA blood pump model using particle image velocimetry (PIV) P Hariharan, KI Aycock, M Buesen, SW Day, BC Good, LH Herbertson, ... Cardiovascular engineering and technology 9, 623-640, 2018 | 40 | 2018 |
Use of the FDA nozzle model to illustrate validation techniques in computational fluid dynamics (CFD) simulations P Hariharan, GA D’Souza, M Horner, TM Morrison, RA Malinauskas, ... PloS one 12 (6), e0178749, 2017 | 39 | 2017 |
Verification benchmarks to assess the implementation of computational fluid dynamics based hemolysis prediction models P Hariharan, G D’Souza, M Horner, RA Malinauskas, MR Myers Journal of biomechanical engineering 137 (9), 094501, 2015 | 38 | 2015 |
A CFD-based Kriging surrogate modeling approach for predicting device-specific hemolysis power law coefficients in blood-contacting medical devices BA Craven, KI Aycock, LH Herbertson, RA Malinauskas Biomechanics and Modeling in Mechanobiology 18, 1005-1030, 2019 | 29 | 2019 |
Time-resolved particle image velocimetry measurements with wall shear stress and uncertainty quantification for the FDA nozzle model JS Raben, P Hariharan, R Robinson, R Malinauskas, PP Vlachos Cardiovascular engineering and technology 7, 7-22, 2016 | 24 | 2016 |
Preliminary results of FDA’s ‘Critical Path’project to validate computational fluid dynamic methods used in medical device evaluation SFC Stewart, S Day, GW Burgreen, EG Paterson, KB Manning, ... ASAIO J 55 (2), 173, 2009 | 22 | 2009 |
Analysis of transitional and turbulent flow through the FDA benchmark nozzle model using laser Doppler velocimetry JO Taylor, BC Good, AV Paterno, P Hariharan, S Deutsch, ... Cardiovascular Engineering and Technology 7, 191-209, 2016 | 20 | 2016 |
Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters RA Robinson, LH Herbertson, SS Das, RA Malinauskas, WF Pritchard, ... Medical Devices: Evidence and Research, 49-57, 2013 | 19 | 2013 |
Decreased hemodialysis circuit pressures indicating postpump tubing kinks: a retrospective investigation of hemolysis in five patients RA Malinauskas Hemodialysis International 12 (3), 383-393, 2008 | 19 | 2008 |
A reusable, compliant, small volume blood reservoir for in vitro hemolysis testing SE Olia, LH Herbertson, RA Malinauskas, MV Kameneva Artificial organs 41 (2), 175-178, 2017 | 18 | 2017 |