Fatigue effects during a single session of automated static threshold perimetry. C Hudson, JM Wild, EC O'Neill Investigative ophthalmology & visual science 35 (1), 268-280, 1994 | 220 | 1994 |
Visual field defects associated with vigabatrin therapy MC Lawden, T Eke, C Degg, GFA Harding, JM Wild Journal of Neurology, Neurosurgery & Psychiatry 67 (6), 716-722, 1999 | 205 | 1999 |
Characteristics of a unique visual field defect attributed to vigabatrin JM Wild, C Martinez, G Reinshagen, GFA Harding Epilepsia 40 (12), 1784-1794, 1999 | 176 | 1999 |
Prevalence of visual field loss following exposure to vigabatrin therapy: a systematic review MJ Maguire, K Hemming, JM Wild, JL Hutton, AG Marson Epilepsia 51 (12), 2423-2431, 2010 | 160 | 2010 |
Referral patterns to an ophthalmic outpatient clinic by general practitioners and ophthalmic opticians and the role of these professionals in screening for ocular disease. RJ Harrison, JM Wild, AJ Hobley British Medical Journal 297 (6657), 1162-1167, 1988 | 153 | 1988 |
The influence of the learning effect on automated perimetry in patients with suspected glaucoma JM Wild, M Dengler‐Harles, AET Searle, EC O'neill, SJ Crews Acta ophthalmologica 67 (5), 537-545, 1989 | 146 | 1989 |
Between-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm. JM Wild, IE Pacey, SA Hancock, IA Cunliffe Investigative ophthalmology & visual science 40 (6), 1152-1161, 1999 | 141 | 1999 |
The SITA perimetric threshold algorithms in glaucoma JM Wild, IE Pacey, EC O’Neill, IA Cunliffe Investigative ophthalmology & visual science 40 (9), 1998-2009, 1999 | 137 | 1999 |
Serial examination of the normal visual field using octopus automated projection perimetry evidence for a learning effect JM Wood, JM Wild, MK Hussey, SJ Crews Acta ophthalmologica 65 (3), 326-333, 1987 | 133 | 1987 |
Electrophysiological evidence of early functional damage in glaucoma and ocular hypertension RV North, AL Jones, N Drasdo, JM Wild, JE Morgan Investigative ophthalmology & visual science 51 (2), 1216-1222, 2010 | 122 | 2010 |
Separating the retinal electrophysiologic effects of vigabatrin: treatment versus field loss GFA Harding, JM Wild, KA Robertson, S Rietbrock, C Martinez Neurology 55 (3), 347-352, 2000 | 112 | 2000 |
The statistical interpretation of blue-on-yellow visual field loss. JM Wild, ID Moss, D Whitaker, EC O'Neill Investigative ophthalmology & visual science 36 (7), 1398-1410, 1995 | 112 | 1995 |
The influence of age-related cataract on blue-on-yellow perimetry. ID Moss, JM Wild, DJ Whitaker Investigative ophthalmology & visual science 36 (5), 764-773, 1995 | 102 | 1995 |
Long‐term follow‐up of baseline learning and fatigue effects in the automated perimetry of glaucoma and ocular hypertensive patients JM Wild, AET Searle, M Dengler‐Harles, EC O'Neill Acta ophthalmologica 69 (2), 210-216, 1991 | 102 | 1991 |
Short wavelength automated perimetry JM Wild Acta Ophthalmologica Scandinavica 79 (6), 546-559, 2001 | 97 | 2001 |
Statistical aspects of the normal visual field in short-wavelength automated perimetry. JM Wild, RP Cubbidge, IE Pacey, R Robinson Investigative ophthalmology & visual science 39 (1), 54-63, 1998 | 95 | 1998 |
Detecting vigabatrin toxicity by imaging of the retinal nerve fiber layer JM Wild, CR Robson, AL Jones, IA Cunliffe, PEM Smith Investigative ophthalmology & visual science 47 (3), 917-924, 2006 | 89 | 2006 |
Visual field loss in patients with refractory partial epilepsy treated with vigabatrin: final results from an open-label, observational, multicentre study JM Wild, C Chiron, H Ahn, M Baulac, J Bursztyn, E Gandolfo, I Goldberg, ... CNS drugs 23, 965-982, 2009 | 86 | 2009 |
Time-related variation in normal automated static perimetry AET Searle, JM Wild, DE Shaw, EC O'Neill Ophthalmology 98 (5), 701-707, 1991 | 86 | 1991 |
Vigabatrin and epilepsy: lessons learned JM Wild, H Ahn, M Baulac, J Bursztyn, C Chiron, E Gandolfo, AB Safran, ... Epilepsia 48 (7), 1318-1327, 2007 | 84 | 2007 |