Следене
Moritz Zaiss
Moritz Zaiss
Ph.D.
Потвърден имейл адрес: tuebingen.mpg.de - Начална страница
Заглавие
Позовавания
Позовавания
Година
Pros and cons of ultra-high-field MRI/MRS for human application
ME Ladd, P Bachert, M Meyerspeer, E Moser, AM Nagel, DG Norris, ...
Progress in nuclear magnetic resonance spectroscopy 109, 1-50, 2018
4512018
Chemical exchange saturation transfer (CEST) and MR Z-spectroscopy in vivo: a review of theoretical approaches and methods
M Zaiss, P Bachert
Physics in Medicine & Biology 58 (22), R221, 2013
3342013
Inverse Z‐spectrum analysis for spillover‐, MT‐, and T1‐corrected steady‐state pulsed CEST‐MRI – application to pH‐weighted MRI of acute stroke
M Zaiss, J Xu, S Goerke, IS Khan, RJ Singer, JC Gore, DF Gochberg, ...
NMR in biomedicine 27 (3), 240-252, 2014
3272014
Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra
M Zaiß, B Schmitt, P Bachert
Journal of magnetic resonance 211 (2), 149-155, 2011
3222011
Correction of B1‐inhomogeneities for relaxation‐compensated CEST imaging at 7 T
J Windschuh, M Zaiss, JE Meissner, D Paech, A Radbruch, ME Ladd, ...
NMR in biomedicine 28 (5), 529-537, 2015
2392015
Relaxation-compensated CEST-MRI of the human brain at 7 T: unbiased insight into NOE and amide signal changes in human glioblastoma
M Zaiss, J Windschuh, D Paech, JE Meissner, S Burth, B Schmitt, ...
Neuroimage 112, 180-188, 2015
2292015
Exchange‐dependent relaxation in the rotating frame for slow and intermediate exchange–modeling off‐resonant spin‐lock and chemical exchange saturation transfer
M Zaiss, P Bachert
NMR in Biomedicine 26 (5), 507-518, 2013
2292013
An overview of CEST MRI for non-MR physicists
B Wu, G Warnock, M Zaiss, C Lin, M Chen, Z Zhou, L Mu, D Nanz, ...
EJNMMI physics 3, 1-21, 2016
2172016
On the origins of chemical exchange saturation transfer (CEST) contrast in tumors at 9.4 T
J Xu, M Zaiss, Z Zu, H Li, J Xie, DF Gochberg, P Bachert, JC Gore
NMR in biomedicine 27 (4), 406-416, 2014
1672014
Simultaneous mapping of water shift and B1(WASABI)—Application to field‐Inhomogeneity correction of CEST MRI data
P Schuenke, J Windschuh, V Roeloffs, ME Ladd, P Bachert, M Zaiss
Magnetic resonance in medicine 77 (2), 571-580, 2017
1662017
A combined analytical solution for chemical exchange saturation transfer and semi‐solid magnetization transfer
M Zaiss, Z Zu, J Xu, P Schuenke, DF Gochberg, JC Gore, ME Ladd, ...
NMR in biomedicine 28 (2), 217-230, 2015
1492015
Downfield‐NOE‐suppressed amide‐CEST‐MRI at 7 Tesla provides a unique contrast in human glioblastoma
M Zaiss, J Windschuh, S Goerke, D Paech, JE Meissner, S Burth, ...
Magnetic resonance in medicine 77 (1), 196-208, 2017
1382017
Assessing the predictability of IDH mutation and MGMT methylation status in glioma patients using relaxation-compensated multipool CEST MRI at 7.0 T
D Paech, J Windschuh, J Oberhollenzer, C Dreher, F Sahm, JE Meissner, ...
Neuro-oncology 20 (12), 1661-1671, 2018
1342018
Snapshot‐CEST: optimizing spiral‐centric‐reordered gradient echo acquisition for fast and robust 3D CEST MRI at 9.4 T
M Zaiss, P Ehses, K Scheffler
NMR in Biomedicine 31 (4), e3879, 2018
1082018
Optimization of pulse train presaturation for CEST imaging in clinical scanners
B Schmitt, M Zaiß, J Zhou, P Bachert
Magnetic resonance in medicine 65 (6), 1620-1629, 2011
1052011
T1ρ-weighted dynamic glucose-enhanced MR imaging in the human brain
D Paech, P Schuenke, C Koehler, J Windschuh, S Mundiyanapurath, ...
Radiology 285 (3), 914-922, 2017
1032017
Adiabatically prepared spin‐lock approach for T1ρ‐based dynamic glucose enhanced MRI at ultrahigh fields
P Schuenke, C Koehler, A Korzowski, J Windschuh, P Bachert, ME Ladd, ...
Magnetic resonance in medicine 78 (1), 215-225, 2017
1022017
QUESP and QUEST revisited–fast and accurate quantitative CEST experiments
M Zaiss, G Angelovski, E Demetriou, MT McMahon, X Golay, K Scheffler
Magnetic resonance in medicine 79 (3), 1708-1721, 2018
1002018
MR imaging of protein folding in vitro employing Nuclear‐Overhauser‐mediated saturation transfer
M Zaiss, P Kunz, S Goerke, A Radbruch, P Bachert
NMR in biomedicine 26 (12), 1815-1822, 2013
982013
Characterization of creatine guanidinium proton exchange by water‐exchange (WEX) spectroscopy for absolute‐pH CEST imaging in vitro
S Goerke, M Zaiss, P Bachert
NMR in Biomedicine 27 (5), 507-518, 2014
922014
Системата не може да изпълни операцията сега. Опитайте отново по-късно.
Статии 1–20