Michael King
Michael King
Verified email at umassmed.edu
Title
Cited by
Cited by
Year
Development and application of the new dynamic Nurbs-based Cardiac-Torso (NCAT) phantom.
WP Segars
6192002
A dual-photopeak window method for scatter correction
MA King, GJ Hademenos, SJ Glick
J Nucl Med 33 (4), 605-12, 1992
2531992
Two-dimensional filtering of SPECT images using the Metz and Wiener filters
MA King, RB Schwinger, PW Doherty, BC Penney
Journal of Nuclear Medicine 25 (11), 1234-1240, 1984
2131984
Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps
MA King, BMW Tsui, TS Pan
Journal of Nuclear Cardiology 2 (6), 513-524, 1995
1851995
Channelized Hotelling and human observer correlation for lesion detection in hepatic SPECT imaging
HC Gifford, MA King, DJ de Vries, EJ Soares
Journal of Nuclear Medicine 41 (3), 514-521, 2000
1842000
Monte Carlo calculations in nuclear medicine: Applications in diagnostic imaging
M Ljungberg, SE Strand, MA King
CRC Press, 2012
1812012
Monte Carlo calculations in nuclear medicine: Applications in diagnostic imaging
M Ljungberg, SE Strand, MA King
CRC Press, 2012
1812012
Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imaging
SJ Glick, BC Penney, MA King, CL Byrne
IEEE transactions on medical imaging 13 (2), 363-374, 1994
1461994
A Wiener filter for nuclear medicine images
MA King, PW Doherty, RB Schwinger, BC Penney
Medical physics 10 (6), 876-880, 1983
1341983
Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms
MA King, BMW Tsui, TS Pan, SJ Glick, EJ Soares
Journal of nuclear cardiology 3 (1), 55-64, 1996
1261996
A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging
PH Pretorius, MA King, BMW Tsui, KJ LaCroix, W Xia
Medical Physics 26 (11), 2323-2332, 1999
1231999
Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom
PH Pretorius, W Xia, MA King, BMW Tsui, TS Pan, BJ Villegas
Journal of Nuclear Medicine 38 (10), 1528-1534, 1997
1201997
Comparison of four scatter correction methods using Monte Carlo simulated source distributions
M Ljungberg, MA King, GJ Hademenos, SE Strand
Journal of Nuclear Medicine 35 (1), 143-151, 1994
1201994
A study of irradiated bone: I. Histopathologic and physiologic changes
MA King, GW Casarett, DA Weber
Journal of Nuclear Medicine 20 (11), 1142-1149, 1979
1141979
SPECT volume quantitation: influence of spatial resolution, source size and shape, and voxel size
MA King, DT Long, AB Brill
Medical physics 18 (5), 1016-1024, 1991
1131991
A comparison of human and model observers in multislice LROC studies
HC Gifford, MA King, PH Pretorius, RG Wells
IEEE transactions on medical imaging 24 (2), 160-169, 2005
1122005
Search for scalar leptoquarks in pp collisions at ¬= ¬ 13 TeV with the ATLAS experiment
M Aaboud, G Aad, B Abbott, J Abdallah, B Abeloos, R Aben, OS AbouZeid, ...
New journal of physics, 2016
1102016
Investigation of causes of geometric distortion in 180 degrees and 360 degrees angular sampling in SPECT.
K Knesaurek, MA King, SJ Glick, BC Penney
Journal of nuclear medicine: official publication, Society of Nuclear†…, 1989
1061989
Aspects of age variation in facial morphology affecting biometrics
E Patterson, A Sethuram, M Albert, K Ricanek, M King
2007 First IEEE International Conference on Biometrics: Theory, Applications†…, 2007
1052007
Survival of autotransfused red blood cells recovered from the surgical field during cardiovascular operations
J Ansell, N Parrilla, M King, L Fournier, I Szymanski, P Doherty, ...
The Journal of thoracic and cardiovascular surgery 84 (3), 387-391, 1982
1041982
The system can't perform the operation now. Try again later.
Articles 1–20