Measurement of lower leg compression in vivo: recommendations for the performance of measurements of interface pressure and stiffness H Partsch, M Clark, S Bassez, JP BENIGNI, F Becker, V Blazek, J Caprini, ... Dermatologic surgery 32 (2), 224-233, 2006 | 316 | 2006 |
Chirp optical coherence tomography of layered scattering media U Haberland, V Blazek, HJ Schmitt Journal of Biomedical Optics 3 (3), 259-266, 1998 | 210 | 1998 |
Synergetic Interpretation of Patterned Vasomotor Activity in Microvascuiar Perfusion: Discrete Effects of Myogenic and Neurogenic Vasoconstriction as well as Arterial and … H Schmid-Schönbein, S Ziege, R Grebe, V Blazek, R Spielmann, ... International Journal of Microcirculation 17 (6), 346-359, 1997 | 161 | 1997 |
Remote monitoring of breathing dynamics using infrared thermography CB Pereira, X Yu, M Czaplik, R Rossaint, V Blazek, S Leonhardt Biomedical optics express 6 (11), 4378-4394, 2015 | 157 | 2015 |
Photoplethysmography imaging: a new noninvasive and noncontact method for mapping of the dermal perfusion changes T Wu, V Blazek, HJ Schmitt Optical techniques and instrumentation for the measurement of blood …, 2000 | 123 | 2000 |
Contactless mapping of rhythmical phenomena in tissue perfusion using PPGI M Huelsbusch, V Blazek Medical Imaging 2002: Physiology and Function from Multidimensional Images …, 2002 | 121 | 2002 |
In-ear vital signs monitoring using a novel microoptic reflective sensor S Vogel, M Hülsbusch, T Hennig, V Blazek, S Leonhardt IEEE Transactions on Information Technology in Biomedicine 13 (6), 882-889, 2009 | 97 | 2009 |
Noncontact monitoring of respiratory rate in newborn infants using thermal imaging CB Pereira, X Yu, T Goos, I Reiss, T Orlikowsky, K Heimann, B Venema, ... IEEE transactions on Biomedical Engineering 66 (4), 1105-1114, 2018 | 77 | 2018 |
Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: results of a human hypoxia study B Venema, N Blanik, V Blazek, H Gehring, A Opp, S Leonhardt IEEE Transactions on Biomedical Engineering 59 (7), 2003-2010, 2012 | 77 | 2012 |
Measuring apparatus for the non-invasive detection of venous and arterial blood flow and drainage disorders V Blazek, V Wienert US Patent 4,494,550, 1985 | 70 | 1985 |
Arrangement for inspecting light waveguide end faces JJ Noll, V Blazek, HJ Schmitt US Patent 4,854,701, 1989 | 61 | 1989 |
Quantitative Photoplethysmography: Basic Facts and Examination Tests for Evaluating Peripheral Vascular Funktions [ie Functions] V Blazek, U Schultz-Ehrenburg VDI-Verlag, 1996 | 59* | 1996 |
Evaluating innovative in-ear pulse oximetry for unobtrusive cardiovascular and pulmonary monitoring during sleep B Venema, J Schiefer, V Blazek, N Blanik, S Leonhardt IEEE journal of translational engineering in health and medicine 1, 2700208 …, 2013 | 58 | 2013 |
Estimation of breathing rate in thermal imaging videos: a pilot study on healthy human subjects C Barbosa Pereira, X Yu, M Czaplik, V Blazek, B Venema, S Leonhardt Journal of clinical monitoring and computing 31, 1241-1254, 2017 | 53 | 2017 |
Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior N Blanik, AK Abbas, B Venema, V Blazek, S Leonhardt Journal of biomedical optics 19 (1), 016012-016012, 2014 | 51 | 2014 |
Value of quantitative photoplethysmography for functional vascular diagnostics U Schultz-Ehrenburg, V Blazek Skin Pharmacology and Physiology 14 (5), 316-323, 2001 | 51 | 2001 |
Neonatal infrared thermography imaging: analysis of heat flux during different clinical scenarios AK Abbas, K Heimann, V Blazek, T Orlikowsky, S Leonhardt Infrared Physics & Technology 55 (6), 538-548, 2012 | 47 | 2012 |
Local group invariance for heart rate estimation from face videos in the wild CS Pilz, S Zaunseder, J Krajewski, V Blazek Proceedings of the IEEE conference on computer vision and pattern …, 2018 | 46 | 2018 |
Contact-free monitoring of circulation and perfusion dynamics based on the analysis of thermal imagery CB Pereira, M Czaplik, N Blanik, R Rossaint, V Blazek, S Leonhardt Biomedical optics express 5 (4), 1075-1089, 2014 | 43 | 2014 |
Local cold exposure test with a new arterial photoplethysmographic sensor in healthy controls and patients with secondary Raynaud's phenomenon M Hahn, C Hahn, M Jünger, A Steins, D Zuder, T Klyscz, A Büchtemann, ... Microvascular research 57 (2), 187-198, 1999 | 43 | 1999 |